EDUARDO TABISI

Sonuçlar 71-80 / 153
Sayfa başına sonuç:
Sıralama ölçütü:
Parça Numarası
Tedarikçi
Underwriters Laboratories
Açıklama
Sağlanmadı
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
164
Eklenme tarihi
27 Eki, 2012
Parça Numarası
Tedarikçi
GENERAL ELECTRIC
Açıklama
A voltage sensitive, electromagnetic type motor starting relay with normally closed snap-action contacts used to disconnect the start capacitor on capacitor-start, induction-run and capacitor-start, capacitor-run motors. The relay has a protective cover which eliminates the need for additional electrical and mechanical protection. A variety of mounting brackets are available. Terminals may be either Quick Connect Tab Type or Screw Type. Typical Applications • Central air conditioner compressors • Submersible pump motors • Motors generally over 1/3 HP with start capacitors
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
86
Eklenme tarihi
27 Eki, 2012
Parça Numarası
Tedarikçi
EMERSON - COPELAND
Açıklama
The Copeland Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor or the Copeland Discus Digital Compressor and the system controller.
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
109
Eklenme tarihi
24 Eki, 2012
Parça Numarası
Tedarikçi
Several Chinese manufacturers
Açıklama
Service Valve is suitable for seperated airconditioner with R22, R407C, R410A as refrigerant, to connect indoor unit and outdoor unit, through operating valve stem clockwise, the valve will be closed, otherwise open it. It can be a checking valve to drain air and add refrigerant during maintaining, also be used in other refrigerating circle systems.
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
121
Eklenme tarihi
21 Eki, 2012
Parça Numarası
Tedarikçi
Several Chinese manufacturers
Açıklama
Service Valve is suitable for seperated airconditioner with R22, R407C, R410A as refrigerant, to connect indoor unit and outdoor unit, through operating valve stem clockwise, the valve will be closed, otherwise open it. It can be a checking valve to drain air and add refrigerant during maintaining, also be used in other refrigerating circle systems.
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
99
Eklenme tarihi
21 Eki, 2012
Parça Numarası
Tedarikçi
Several Chinese manufacturers
Açıklama
Service Valve is suitable for seperated airconditioner with R22, R407C, R410A as refrigerant, to connect indoor unit and outdoor unit, through operating valve stem clockwise, the valve will be closed, otherwise open it. It can be a checking valve to drain air and add refrigerant during maintaining, also be used in other refrigerating circle systems.
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
145
Eklenme tarihi
20 Eki, 2012
Parça Numarası
Tedarikçi
Several Chinese manufacturers
Açıklama
Service Valve is suitable for seperated airconditioner with R22, R407C, R410A as refrigerant, to connect indoor unit and outdoor unit, through operating valve stem clockwise, the valve will be closed, otherwise open it. It can be a checking valve to drain air and add refrigerant during maintaining, also be used in other refrigerating circle systems.
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
64
Eklenme tarihi
20 Eki, 2012
Parça Numarası
Tedarikçi
Several Chinese manufacturers
Açıklama
Service Valve is suitable for seperated airconditioner with R22, R407C, R410A as refrigerant, to connect indoor unit and outdoor unit, through operating valve stem clockwise, the valve will be closed, otherwise open it. It can be a checking valve to drain air and add refrigerant during maintaining, also be used in other refrigerating circle systems.
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
127
Eklenme tarihi
20 Eki, 2012
Parça Numarası
Tedarikçi
EMERSON CLIMATE - COPELAND
Açıklama
SCROLL COMPRESSOR HVAC APPLICATION - DISCHARGE 7/8" - SUCTION 1.3/8" - R407C
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
731
Eklenme tarihi
8 Eki, 2012
Parça Numarası
Tedarikçi
CAREL ITALY
Açıklama
These pressure transducers provide a standard analogue current signal (4 to 20 mA). They are used mainly in refrigeration and air-conditioning applications to measure the pressure in the refrigerant circuits however their high performance also makes them ideal for many other applications. These probes can also be used in refrigerant circuits containing ammonia.
Katkıda Bulunan
Şirket
TECNITOWER SA
Yapılandırmalar mı?
Hayır
İndirmeler
55
Eklenme tarihi
5 Eki, 2012